Postal address : Bronte Works,  Thornton, Bradford,  W.  Yorkshire    BD13 3HD,   Great Britain logo.gif (5741 bytes)

FAX                 :              44(0)1274 831111

Electronic mail:           General Information: mail@equiptex.com

Telephone      :             44( 0)1274 831000

 

This is our old site ...........Please go to............... www.equiptex.com

 

Home
Up

Light Cabinets

Dimensions (mm) CAC 150/120

CAC 150 Width Height Depth
Overall 1560 780 620
Viewing Cavity 1520 570 590
CAC 120
Overall 1300 780 620
Viewing Cavity 1260 570 590
Switch Identification
01 Mains on/off
D65 VeriVide "Artificial Daylight" Fluorescent lamps conforming to the international Standard Illuminant D6500 within the tolerances prescribed in BS 950:Part 1.
D652 Additional level of "Artificial Daylight" for colours of low reflectance factor. Switches D65 and D652 must be depressed together.
TL83
TL84
Philips Triphosphor fluorescent lamps often chosen as a "Point of Sale" illuminant.
F Tungsten Filament lighting required by BS 950:Part 1 as a test for metamerism. (CIE Illuminant 'A').
UV Ultra Violet Blacklight to reveal the presence of fluorescent dyes and bleaches.
Alternative fluorescent lamps can be incorporated if required but three fluorescent light sources plus filament is the maximum for the CAC150, CAC120 and CAC60. The CAC Portable can be supplied with the addition of one extra fluorescent source selected from the following: D75, D50, TL83, TL84, Cool White, Natural, Warm White.
When ordering, please state which lamps are required.

For Electrical Notes please see foot of page.

Dimensions (mm) CAC 60     packed weight 25.45kg
Width Height Depth
Overall 710 570 420
Viewing Cavity 680 360 380
Switch Identification
01 Mains on/off
D65 VeriVide "Artificial Daylight" Fluorescent lamps conforming to the international Standard Illuminant D6500 within the tolerances prescribed in BS 950:Part 1.
D652 Additional level of "Artificial Daylight" for colours of low reflectance factor. Switches D65 and D652 must be depressed together.
TL83
TL84
Philips Triphosphor fluorescent lamps often chosen as a "Point of Sale" illuminant.
F Tungsten Filament lighting required by BS 950:Part 1 as a test for metamerism. (CIE Illuminant 'A').
UV Ultra Violet Blacklight to reveal the presence of fluorescent dyes and bleaches.
Alternative fluorescent lamps can be incorporated if required but three fluorescent light sources plus filament is the maximum for the CAC150, CAC120 and CAC60. The CAC Portable can be supplied with the addition of one extra fluorescent source selected from the following: D75, D50, TL83, TL84, Cool White, Natural, Warm White.
When ordering, please state which lamps are required.

For Electrical Notes please see foot of page.

Dimensions (mm) Portable
Width Height Depth
Overall 670 415 310
Viewing Cavity 630 275 280
Closed 670 315 140
 Switch Identification
01 Mains on/off
D65 VeriVide "Artificial Daylight" Fluorescent lamps conforming to the international Standard Illuminant D6500 within the tolerances prescribed in BS 950:Part 1.
TL83
TL84
Philips Triphosphor fluorescent lamps often chosen as a "Point of Sale" illuminant.
F Tungsten Filament lighting required by BS 950:Part 1 as a test for metamerism. (CIE Illuminant 'A').
UV Ultra Violet Blacklight to reveal the presence of fluorescent dyes and bleaches.
The CAC Portable can be supplied with four fluorescent source selected from the following: D65, D75, D50, TL83, TL84, Cool White, Natural, Warm White, plus Filament.
When ordering, please state which lamps are required.
Product Order Codes
CAC 150/120/60
D652FUV
D65TL84FUV
D65TL83FTL84
D65TL84FTL83
D65TL83FUV
CAC 120/60
D65UVFUV
Portable
D65TL84FUV
D65TL83FTL84
D65TL83FUV
Plus addition of one extra Fluorescent Source

 

Cabinet Interior
All cabinets are normally supplied with the interior coloured grey Ref: 14.40D but they can be supplied with an alternative, Munsell grey N5, if this preference is specified on order.
Other Optional Items
Diffusers are available for the CAC 60, 120 and 150 cabinets, but should be used only when highly specular materials are to be assessed. Add/D to product order code.
Tilting table, to fit the CAC 60, used in testing for metallic metamerism i.e. vehicle finishing, surface coating, metallic foil manufacture. Add /TT to product order code. 45o Fixed Angle Table to fit the CAC 60 cabinet. Add /T45 to product order code.
Whilst every effort is made to keep within the tolerances of BS950 and progressively to improve the performance of our products, no guarantee can be given that there will be no deviation. We reserve the right to modify our equipment at any time.

 Next Page Cutter & Balance